1.2. Features

1.2.1.IM300 functions
Applied in 3-phase 3-wire system and 3-phase 4-wire system . It can measure
and calculate 3-phase voltage, 3-phase current, Zero-sequence current, active
power, reactive power, apparent power,
energy and reactive energy.
Harmonic distortion ratio of voltage and current.( Including total harmonic
distortion ratio THD, odd harmonic distortion ratio , even harmonic distortion
ratio), 2~31st harmonic occupancy of voltage, 2~31st harmonic occupancy of
current, the RMS of voltage and current base wave, etc.
2-ch relay control output
1.2. Features
1.2. 1.IM300 functions .
Applied in 3-phase 3-wire system and 3-phase 4-wire system . It can measure
and calculate 3-phase voltage, 3-phase current, Zero-sequence current, active
power, reactive power, apparent power, power factor, system frequency, active
energy and reactive energy.

Harmonic distortion ratio of voltage and current.( Including total harmonic
distortion ratio THD, odd harmonic distortion ratio, even harmonic distortion
ratio), 2~31st harmonic occupancy of voltage, 2~3 lst harmonic occupancy of
current, the RMS of voltage and current base wave, etc.

2-ch relay control outputs.


4-ch digital inputs, up to 32 SOE (the Sequence of Events) of digital inputs
can be recorded.
1-ch 4 ~ 20mA DC transmission output which can be associated with any
voltage, current, power.

forward/reverse total active energy, reactive energy in four quadrants.

Multi- rate energy statistics (4 rates, 48 time-periods) of the forward/reverse
total active energy, reactive energy in four quadrants.

The value and occurrence time of the maximum forward/reverse active and
reactive power demand. The maximum/ minimum value and occurrence time of
the voltage, current, frequency,
power factor, active power, reactive power,
apparent power.
Unbalanced degree of three-phase voltage and current.
The over limit alarm funetion, such as over-current, zero-current, grounding,
low-voltage, over-voltage, low-frequency, over- frequency, low-power factor, can
be associated with relay outputs.

Checking and modifying the various electrical parameters, running status and
controlling the relays locally.

Communication protocol is MODBUS-RTU.

The clock can be set manually.
Note: The above functions are selected according to the specific models of the
meter (see appendix C). 
1.2.2.High safety and reliability
IM300 can run steadily in the complex power system.
●Elctrostatic discharge immunity test: level 3
●Electric fast transient immunity test : level 3
●The surge immunity test : level 3
●Frequency magnetic field immunity test: level 3
●Oscillation wave immunity test : level 3
●The IP level of panel: IP50, the IP level of shell: IP20
1.2.3. Easy installation
IM300 dimensions conform DIN96 x 96 standard. It can be mounted on the cabinet panel easily.
1.2.4. The wiring of system
●3-phase 4-wire 3CT (3P4W 3CT)
●3-phase 4-wire 1CT (3P4W 1CT)
●3-phase 3-wire 3CT (3P3W 3CT)
●3-phase 3-wire 2CT (3P3W 2CT)
●3-phase 3-wire 1CT (3P3W 1CT)
1.2. 5. The human-machine interface
The LCD screen can display various of information with bright backlighting. It's
very easy to operate IM300 by the human-machine interface.
1.2.6. Application field
Medium and low voltage distribution system, intelligent switch cabinet, load
control system, industrial automation, building automation and Energy management
system.


1.2. Features

1.2.1.IM300 functions
Applied in 3-phase 3-wire system and 3-phase 4-wire system . It can measure
and calculate 3-phase voltage, 3-phase current, Zero-sequence current, active
power, reactive power, apparent power,
energy and reactive energy.
Harmonic distortion ratio of voltage and current.( Including total harmonic
distortion ratio THD, odd harmonic distortion ratio , even harmonic distortion
ratio), 2~31st harmonic occupancy of voltage, 2~31st harmonic occupancy of
current, the RMS of voltage and current base wave, etc.
2-ch relay control output

 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
View History
Related tools
$261.61
$784.80
$1477.40
Business time
9:00-22:00
  • Email:support@rig123.com